Siemens S7
Unterstützte Datentypen
Datentyp | Im Crawler (nur Lesen) | Von SPS unterstützt |
---|
Crawler VarType | Crawler InfluxType | Bits | Symbolisch | Absolut | S7-300/400 | S7-1200 | S7-1500 |
---|
Binärzahlen |
S7_Bool | FLOAT | 1 | | | ✔ | ✔ | ✔ |
S7_Byte | FLOAT | 8 | | | ✔ | ✔ | ✔ |
S7_Word | FLOAT | 16 | | | ✔ | ✔ | ✔ |
S7_DWord | FLOAT | 32 | | | ✔ | ✔ | ✔ |
S7_LWord | FLOAT | 64 | | | | | ✔ |
Ganzzahlen |
S7_SInt | FLOAT | 8 | | | | ✔ | ✔ |
S7_Int | FLOAT | 16 | | | ✔ | ✔ | ✔ |
S7_DInt | FLOAT | 32 | | | ✔ | ✔ | ✔ |
S7_USInt | FLOAT | 8 | | | | ✔ | ✔ |
S7_UInt | FLOAT | 16 | | | | ✔ | ✔ |
S7_UDInt | FLOAT | 32 | | | | ✔ | ✔ |
S7_LInt | FLOAT | 64 | | | | | ✔ |
S7_ULInt | FLOAT | 64 | | | | | ✔ |
Gleitpunktzahlen |
S7_Real | FLOAT | 32 | | | ✔ | ✔ | ✔ |
S7_LReal | FLOAT | 64 | | | | ✔ | ✔ |
Zeiten |
S7_S5Time | STRING | 16 | | | ✔ | | ✔ |
S7_Time | STRING | 32 | | | ✔ | ✔ | ✔ |
FLOAT (Millisek.) | | |
S7_LTime | STRING | 64 | | | | | ✔ |
FLOAT (Nanosek.) | | |
Datum und Uhrzeit |
S7_Date | STRING | 16 | | | ✔ | ✔ | ✔ |
FLOAT (Tage) | | |
S7_Time_Of_Day | STRING | 32 | | | ✔ | ✔ | ✔ |
FLOAT (Millisek.) | | |
S7_LTOD | STRING | 64 | | | | | ✔ |
FLOAT (Ticks) | | |
S7_Date_And_Time | STRING | 64 | | | ✔ | | ✔ |
S7_LDT | STRING | 64 | | | | | ✔ |
S7_DTL | STRING | 96 | | | | ✔ | ✔ |
Zeichen |
S7_Char | STRING | 8 | | | ✔ | ✔ | ✔ |
S7_WChar | STRING | 16 | | | | ✔ | ✔ |
S7_String | STRING | n+2 Bytes | | | ✔ | ✔ | ✔ |
S7_WString | STRING | n+2 Words | | | | ✔ | ✔ |
Array |
S7_Array | | |
| Einzelzugriff auf jedes Element mit seiner spezifischen Adresse | ✔ Max. Dimensionen: 6 Max. Anzahl Bytes: 32.767 | ✔ Max. Dimensionen: 6 Max. Anzahl Bytes: 65.535 | ✔ Max. Dimensionen: 6 Max. Anzahl Bytes: 16.777.216 |
Zeiger |
Pointer | | 48 | | | ✔ | | ✔ |
Any | | 80 | | | ✔ | | ✔ |
Variant | | 0 | | | | ✔ | ✔ |
Modbus TCP
Funktion | Kommentar |
---|
Unterstützte Zugriffsmethoden | READ_COIL, READ_DISCRETE_INPUT, READ_INPUT_REGISTER, READ_HOLDING_REGISTER |
---|
Unterstützte Datentypen | BOOLEAN*, INT16, UINT16, INT32, UINT32, INT64, UINT64, FLOAT, DOUBLE *Boolean nur für Bit-level Zugriffsmethoden (read coils, read discrete input) unterstützt. |
---|
Slave ID (Modbus RTU) | Bei Modbus RTU kann die “Slave ID” angegeben werden. Standard = 1 |
---|
Byte-Reihenfolge (endianness) | Big-endian*, little-endian* (Standard) * Für Datentypen größer als 16 Bit (INT32, UINT32, INT64, UINT64, FLOAT, DOUBLE). Definiert in welchem REGISTER (nicht Bytes) das höchste Bit enthält. Byte-Reihenfolge ist ein optionaler Konfigurationsparameter. Ist eine Abweichung vom Standard erforderlich, kontaktieren Sie bitte den Support. |
---|